I AM A DENTIST

According to the applicable rules and regulations, I declare under my own responsibilities to be a dentist and therefore I am authorized to read the contents of this web site.

Scientifica implantology

Sweden& Martina offers to dentists the opportunity to promptly get an update on the international scientific studies on its implant systems with the volumes SCIENTIFICA, where you can find the abstracts of all publications in the most relevant international papers specialized in implantology. Please fill in the form to get one volume free of charge. For your convenience papers are classified based on their subjects; by clicking on each title, you can see a short summary of the study.

Request for material

Canullo L., Tallarico M., Peñarrocha-Oltra D., Monje A., Wang H.L., Peñarrocha-Diago M.

IMPLANT ABUTMENTS CLEANING BY PLASMA OF ARGON: FIVE YEARS FOLLOW-UP OF A RCT

J Periodontol. 2016 Apr;87(4):434-42. doi: 10.1902/jop.2015.150549. Epub 2015 Nov 12

This five-year study conducted on Premium implants which were immediately loaded shows the long-term benefits of the chair-side...

Canullo L., Genova T., Tallarico M., Gautier G., Mussano F., Botticelli D.

PLASMA OF ARGON AFFECTS THE EARLIEST BIOLOGICAL RESPONSE OF DIFFERENT IMPLANT SURFACES: AN IN VITRO COMPARATIVE STUDY

J Dent Res. 2016 May;95(5):566-73. doi: 10.1177/0022034516629119. Epub 2016 Feb 4

This in vitro study demonstrates the benefits of cleaning implant surfaces with plasma of Argon in terms of protein adsorption during the...

Annunziata M., Canullo L., Donnarumma G., Caputo P., Nastri L., Guida L.

BACTERIAL INACTIVATION/STERILIZATION BY ARGON PLASMA TREATMENT ON CONTAMINATED TITANIUM IMPLANT SURFACES: IN VITRO STUDY

Medicina Oral Patologia Oral y Cirurgía Bucal, 2016 Jan1; 21(1): e118-21, doi 10.4317/medoral.20845

The authors assessed in vitro the decontamination efficacy of Plasma of argon on titanium discs of different degrees of roughness, which...

García B., Camacho F., Peñarrocha D., Tallarico M., Pérez S., Canullo L.

INFLUENCE OF PLASMA CLEANING PROCEDURE ON THE INTERACTION BETWEEN SOFT TISSUE AND ABUTMENTS: A RANDOMIZED CONTROLLED HISTOLOGIC STUDY

Clin Oral Implants Res. 2016 Aug 23. Doi: 10.1111/clr.12953. [Epub ahead of print]

30 patients with 30 implants were split into two groups according to the type of abutment received: The Test Group (abutment cleaned with...

Canullo L., Tallarico M., Peñarrocha M., García B., Peñarrocha D.

PLASMA OF ARGON CLEANING TREATMENT ON IMPLANT ABUTMENTS IN PERIODONTALLY HEALTHY PATIENTS: FIVE YEARS POST-LOADING RESULTS OF AN RCT

Clin. Oral Impl. Res. 27 (Suppl. 13), 2016, EAO Paris

One implant was placed in 18 periodontally healthy patients, who were subsequently split into either the control group (abutment cleaned...

Canullo L., Tallarico M., Peñarrocha D., Meloni S. M., Peñarrocha M.

IMPACT OF ABUTMENT CLEANING ON PERI-IMPLANT TISSUES: 5-YEARS RCT

Eur J Oral Implantol 2016, 9 (3Suppl 2):S9-S52

The aim of this five-year study on 30 patients with thin gingival biotype was to compare the use of abutments cleaned with plasma of Argon...

Micarelli C., Canullo L., Grusovin M.G., Peñarrocha Oltra D.

CELL ADHESION TO TITANIUM ABUTMENTS AFTER DIFFERENT CLEANING PROCEDURES

Clinical Oral Implants Research 2013; 24 (Suppl. 9),79?102

The use of argon plasma for the cleaning of implant abutments accelerates early cellular adhesion of the fibroblasts, thus promoting the...

Canullo L., Cassinelli C., Götz W., Tarnow D.

PLASMA OF ARGON ACCELERATES MURINE FIBROBLAST ADHESION IN EARLY STAGES OF TITANIUM DISK COLONIZATION

The International Journal of Oral & Maxillofacial Implants 2013;28(4):957-62

The cleaning of titanium abutments with argon plasma accelerates the adhesion of the fibroblasts from the earliest hours onwards, promoting...

Canullo L., Peñarrocha Oltra D., Clementini M., Iannello G., Micarelli C.

IMPACT OF PLASMA OF ARGON CLEANING TREATMENT ON IMPLANT ABUTMENTS IN PATIENTS WITH A HISTORY OF PERIODONTAL DISEASE AND THIN BIOTYPE: RADIOGRAPHIC RESULTS AT 24-MONTH FOLLOW-UP OF A RCT

Clinical Oral Implants Research 2015;26(1):8-14

Even in patients with a previous periodontal anamnesis, the combined use of Plasma cleaning, Platform Switching and One-Abutment-One-Time...

Canullo L., Peñarrocha Oltra D., Micarelli C., Massidda O., Bazzoli M.

RISPOSTA DEI TESSUTI DURI ALLA PULIZIA CON PLASMA DI ARGON/STERILIZZAZIONE DI PILASTRI IN TITANIO INDIVIDUALIZZATI, VS PULIZIA DI 5 SECONDI CON VAPORE: RISULTATI DI UN STUDIO CONTROLLATO RANDOMIZZATO IN PAZIENTI CON UNA SITUAZIONE PARODONTALE FAVOREV

European Journal of Oral Implantology 2013;6(3):251-60

This publication confirms the preliminary results presented at the EAO 2013 Congress. Plasma cleaning is effective in the preservation of...